Six-panel urine drug test cup with built-in adulteration and specimen validity checks. Results in five minutes.
Why choose VinScreen 6
- Verified to the current standard — independently verified by RASL to AS/NZS 4308:2023, including the revised 150 ng/mL cocaine cut-off.
- All-in-one cup — collection, drug screening and specimen validity testing in a single sealed device. No decanting, no separate adulteration strip.
- Six validity checks built in — pH, specific gravity, oxidants, creatinine, nitrite and glutaraldehyde, read directly off the cup.
- External temperature strip — catches substituted samples, which chemical checks alone will not detect.
- Five-minute read — drug results at five minutes, stable for up to 60 minutes, so a collector can process several donors without losing a result.
- Matched against laboratory methods — 94.3% to 100% agreement with GC/MS across all six panels in manufacturer testing.
- Tested for interference — no interference from more than 40 common substances including caffeine, ibuprofen, paracetamol, aspirin and ethanol at 100 µg/mL.
Drug panels and cut-off levels
| Drug class | Abbrev. | Calibrator | Cut-off |
|---|---|---|---|
| Amphetamine | AMP | D-Amphetamine | 300 ng/mL |
| Methamphetamine | MET | D-Methamphetamine | 300 ng/mL |
| Cocaine | COC | Benzoylecgonine | 150 ng/mL |
| Opiates | OPI | Morphine | 300 ng/mL |
| Benzodiazepines | BZO | Oxazepam | 200 ng/mL |
| Cannabis | THC | 11-nor-Δ9-THC-9-COOH | 50 ng/mL |
Specimen validity and integrity checks
A donor attempting to defeat a urine screen has three options: substitute someone else's sample or a synthetic one, dilute their own, or add a masking agent. This cup checks for all three.
Substitution is caught by the external temperature strip — read it immediately after collection. A sample outside the expected range did not come from the donor in front of you. No chemical check will tell you this.
Dilution and adulteration are caught by the six reagent pads below, read against the supplied colour chart at three to five minutes.
| Check | Normal range | What it identifies |
|---|---|---|
| pH | 4 – 9 | Acid or alkaline adulteration |
| Specific gravity | 1.003 – 1.030 | Dilution or substitution |
| Oxidants / PCC | None present | Bleach, peroxide, pyridinium chlorochromate |
| Creatinine | 20 – 300 mg/dL | Dilution |
| Nitrite | Below 15 mg/dL | Nitrite-based masking agents |
| Glutaraldehyde | None present | Commercial masking products |
How to use
- Allow the device to reach room temperature (15–30°C). Do not open the pouch until you are ready to test.
- Remove the cup from the sealed pouch and write the donor name or ID in the space provided.
- Collect the urine sample directly in the cup.
- Read the temperature strip immediately — within four minutes of collection, per standard collection practice.
- Read the adulteration pads against the colour chart at three to five minutes.
- Read the drug results at five minutes. Results remain stable for 60 minutes.
Always follow the Instructions for Use supplied with the kit.
How to interpret results
Note that a visible test line means negative. This is the opposite of what people often expect.
- Negative — a red or pink line appears next to T1 or T2 under the drug name. Faint or thin lines still count as negative.
- Preliminary positive — no line appears next to T1 or T2 for that drug. Send the sample for laboratory confirmation.
- Invalid — no line next to C on one or more strips. Discard and retest with a new device.
Do not read results after 60 minutes.
Screening results are preliminary. Any non-negative result should be confirmed by laboratory testing in accordance with your workplace policy.
What's included
- VinScreen 6-panel urine test cup with integrated adulteration strip and external temperature strip
- Colour comparison chart
- Instructions for Use
Best for
- Pre-employment, random, post-incident and fitness-for-duty testing
- Mining, construction and heavy industry
- Transport, logistics and agriculture
- Drug testing service providers and accredited collectors
Frequently asked questions
Can prescription medication cause a preliminary positive?
Yes. The manufacturer states this test does not distinguish between drugs of abuse and certain medications, and may give preliminary positive results where tricyclic antidepressants, barbiturates, benzodiazepines, methadone, buprenorphine or opiates have been taken — including at normal therapeutic doses. Any non-negative result should be confirmed by a laboratory before it is acted on.
Will it pick up MDMA (ecstasy)?
Sometimes, but not reliably. MDMA registers on the methamphetamine panel, but it takes around six times as much MDMA as methamphetamine to trigger a result — roughly 1,750 ng/mL against the 300 ng/mL methamphetamine cut-off. A large or recent dose may register; a smaller or older one may not. It also means a preliminary positive on the methamphetamine panel doesn't tell you which substance was present, which is one reason laboratory confirmation matters.
If MDMA detection matters to your programme, choose a different device. Three options in our range handle it properly:
- SalivaTracer saliva range — MDMA is detected at 50 ng/mL, the same cut-off as methamphetamine. No sensitivity penalty at all. The best option if oral fluid suits your collection process.
- Maxi Clear 15 Urine Drug Test Cup — includes a dedicated MDMA strip, so MDMA is reported separately rather than inferred from the methamphetamine panel.
- 7 Drugs Urine Drug Test Dip Card — also carries a dedicated MDMA strip, in a lower-cost dip card format.
Not sure which suits your programme? Get in touch and we'll talk through the options, or request a quote. Either way we respond within 4 business hours.
Which opiates does it detect?
Codeine, heroin, hydrocodone and hydromorphone all register on the opiates panel alongside morphine. As with methamphetamine, a positive identifies the drug class rather than the specific substance. Note that oxycodone does not reliably register on an opiates panel — if you need oxycodone screening, it requires its own panel.
How accurate is it against laboratory testing?
Manufacturer testing against GC/MS showed 94.3% to 100% agreement across all six panels, and over 99% agreement at ±50% of cut-off across nine operators and 20 testing days.
Will common medications interfere?
No interference was found from more than 40 substances tested at 100 µg/mL, including paracetamol, aspirin, ibuprofen, caffeine, ethanol, ranitidine and dextromethorphan.
How long are drugs detectable in urine?
Detection windows vary by drug, dose and individual factors. For workplace decisions, rely on your policy and confirmatory testing.
Buying for a workplace?
Corporate pricing, 14-day accounts and purchase orders are available. Request a quote — we respond within 4 business hours.
Need to talk it through first? Contact us and we'll help you work out which device fits your testing programme.
Full Description
Full Description
The VinScreen 6-panel urine drug test cup is a single-step integrated device that screens for six drug classes and simultaneously assesses specimen validity. Collection, drug screening and adulteration testing all take place in one sealed cup, which removes the decanting step and the separate adulteration strip used in older workflows.
Six validity checks are built into the cup — pH, specific gravity, oxidants, creatinine, nitrite and glutaraldehyde. These cover the methods most commonly used to defeat a urine screen: dilution, substitution, and commercial masking agents. For workplace programmes where sample integrity may be challenged, having the validity result on the same device as the drug result simplifies the evidence trail.
Drug results are read at five minutes and remain stable for up to 60 minutes, which allows a collector to process multiple donors in sequence. Adulteration pads are read against the supplied colour chart at three to five minutes.
In manufacturer testing against GC/MS and LC/MS reference methods, agreement ranged from 94.3% to 100% across all six panels, with over 99% agreement at ±50% of cut-off in precision testing across nine operators over 20 non-consecutive days.
Supplied in boxes of 25, with pricing available for 100, 250 and 500 unit quantities.
Specification
Specification
ProductVinScreen 6-Panel Urine Drug Test Cup with Adulteration StripSample typeUrineFormatIntegrated single-use collection and test cupPanelsAMP / MET / COC / OPI / BZO / THCCut-offsAMP 300 · MET 300 · COC 150 · OPI 300 · BZO 200 · THC 50 ng/mLValidity checkspH · Specific gravity · Oxidants/PCC · Creatinine · Nitrite · GlutaraldehydeDrug read time5 minutes, stable to 60 minutesAdulteration read time3–5 minutesStorage15–30°CStandardIndependently verified by RASL to AS/NZS 4308:2023Pack sizes25 / 100 / 250 / 500 kitsIFU referenceRP5802520 (01/07/2025)